The Mexico range of floor-standing heat only boilers from Ideal are the perfect solution for the replacement installation.
Perfect for situations when an old standard efficiency boiler is being taken out, the Mexico offers a quick and hassle free installation and benefits from a pre-piping frame which allows all gas connections to be made before the boiler is slid into place. No compartment ventilation means the boiler can be installed under worktops and behind cupboard doors, while a range of flue options, both horizontal and vertical, provide advanced siting flexibility.
Recommended by the Energy Saving Trust, the Mexico is available in the choice of five outputs and comes complete with an easy to use temperature control panel featuring a status and diagnostics display.
Complete with a one year parts and labour warranty and with additional extended warranty options available, the Ideal Mexico provides straightforward heating control from a single floor standing appliance.
| 15 | 18 | 24 | 30 | 36 | |
|---|---|---|---|---|---|
| Casing dimensions (h w d) mm | |||||
| Height | 850 | 850 | |||
| Width | 450 | 450 | |||
| Depth | 530 | 530 | |||
| Weight (packed kg) | 54 | 74 | |||
| Maximum Installation Weight (kg) | 47 | 67 | |||
| CH output (kW) Min/Max @ 70C | 8.8 - 14.6 | 8.8 - 18.2 | 8.8 - 23.4 | 10.6 - 30.1 | 10.6 - 37.0 |
| CH output (kW) Min/Max @ 40C | 9.6 - 15.5 | 9.6 - 19.2 | 9.6 - 25.1 | 11.4 - 32.8 | 11.4 - 39.8 |
| DHW output (kW) Max | N/A | N/A | |||
| DHW flow rate l/min. 35°C rise | N/A | N/A | |||
| SEDBUK rating | Band A | Band A | |||
| SEDBUK % | 90.40% | 90.30% | 90.20% | 90.40% | 90.70% |
| NOx Classification | Class 5 | Class 5 | |||
| Adjustable to LPG | No | No | |||
| 15 | 18 | 24 | 30 | 36 | |
|---|---|---|---|---|---|
| Heat exchanger material | Cast Aluminium - silicon alloy | Cast Aluminium - silicon alloy | |||
| Burner type | Downward firing pre-mix burner | Downward firing pre-mix burner | |||
| Fully modulating | Yes | Yes | |||
| DHW plate heat exchanger | N/A | N/A | |||
| Integrated hydroblock | N/A | N/A | |||
| Suitable for sealed systems | Yes | Yes | |||
| Suitable for open-vent systems | Yes | Yes | |||
| Filling loop | No | No | |||
| Pre-wired mains lead | No | No | |||
| Flow regulator | N/A | N/A | |||
| Inbuilt system bypass | No | No | |||
| Inbuilt condensate trap/siphon | Yes | Yes | |||
| Inbuilt boiler frost protection | Yes | Yes | |||
| Zero compartment ventilation | Yes | Yes | |||
| 15 | 18 | 24 | 30 | 36 | |
|---|---|---|---|---|---|
| Top (mm) (from top of boiler) | 20 | 20 | |||
| Side (mm) | 5 | 5 | |||
| Bottom (mm) | N/A | N/A | |||
| Front (mm) | 450 | 450 | |||
| User display | Alpha Numeric | Alpha Numeric | |||
| User interface | Digital display & manual controls | Digital display & manual controls | |||
| Diagnostics | Fault codes | Fault codes | |||
| User adjustable | Yes | Yes | |||
| ‘Eco’ setting on CH | No | No | |||
| Inbuilt Programmer | No | No | |||
| 15 | 18 | 24 | 30 | 36 | |
|---|---|---|---|---|---|
| Pre-piping kit | Yes | Standard | |||
| Stand-off kit | N/A | N/A | |||
| Upward piping kit | N/A | N/A | |||
| Max horizontal | 6m | 3m | |||
| Max vertical | 8m | 5m | |||
| Powered Vertical | N/A | N/A | |||