Easy to operate, the Ideal solar controller provides the temperature selection setting for the cylinder and uses two temperature sensors to determine when the pump is run to gain solar energy from the panels. The solar panel temperature must always be more than 4ÂșC greater than the cylinder before the controller allows the pump to run.
| Controller | Spec. |
|---|---|
| Operating voltage | 230V 50Hz |
| Internal consumption | ≤ 1W |
| 1 output | 1 x Switch output relay max. 800W |
| Output protected against overload and short circuits | Fuse: 250V 4A MT |
| Display | Animated backlight LCD display |
| Electrical protection | IP 20 |
| Operation temperature range | 0 to + 45°C |
| Weight | 250 g |
| Dimensions | 136W x 133H x 37D (mm) |
| 2 x PT1000 temperature Sensors | 1.5 m silicon cable (Cylinder & solar panel) |